Buchi Logo
  • Product overzicht
    • Evaporation Solutions
      • Rotavapor R-210/R-215
      • Rotavapor R II
      • Rotavapor R 3
      • Vacuum Solutions
      • Vacuum Pump V-700
      • Vacuum Pump V-710
      • Vacuum Controller V-850/V-855
      • Vacuum Modules EasyVac/LabVac
      • Recirculation Chiller
      • Glass Oven B-585 Kugelrohr
      • Glass Oven B-585 Drying
      • 50 jaar rotatieverdamper
    • Industrial Evaporation
      • Rotavapor R-220 SE
      • Rotavapor R-220 EX
      • Rotavapor R-250
      • Rotavapor R-250 EX
      • Chiller for R-220 SE
    • Spray Drying
      • Nano Spray Dryer B-90
      • Mini Spray Dryer B-290
      • Inert Loop B-295
      • Dehumidifier B-296
      • Encapsulator B-390 / B-395 Pro
    • Melting Point
      • Melting Point M-560
      • Melting Point M-565
      • Sample Loader M-569
    • Parallel Evaporation
      • Multivapor P-6/P-12
      • Syncore Polyvap
      • Syncore Analyst
      • SPE & Evaporation
    • Preparative Chromatography
      • Flash Chromatography
      • Flash Pump Systems
      • Isocratic Pump System
      • Gradient Pump System
      • Cartridger C-670
      • Prepacked Cartridges
      • Glass Columns C-690
      • Plunger Columns C-695
      • Fraction Collector C-660
      • DAD-Detector C-640
      • Chart Recorders
      • SepacoreRecord Software
      • SepacoreControl Software
    • Kjeldahl Solutions
      • Digestion
      • Distillation
      • Wet Digester B-440
      • Scrubber K-415
    • Extraction Solutions
      • Classical Extraction
      • Pressurized Solvent Extraction
      • Sample Preparation
    • NIRSolutions
      • NIRFlex N-500
      • NIRFlex Solids
      • NIRFlex Liquids
      • NIRFlex Fiber Optic Solids
      • NIRFlex Fiber Optic Liquids
      • NIRFlex Solids Transmittance
      • NIRMaster
      • NIRWare
      • NIRCal
      • Libraries
      • Pre-Calibrations
      • NIROnline
  • Applicaties
    • zoeken
    • verdamping & synthese
    • pre-kalibraties
    • Spray Dryer Application Finder
    • Kjeldahl
    • Extraction
    • Case Studies
    • best@buchi
    • literatuur
    • applicatie ondersteuning
  • Service & Support
    • Technische ondersteuning
    • Handleidingen
    • Veelgestelde vragen
    • Certificaten
    • Persoonlijk advies
    • Regelgeving
    • Contact
  • Over BUCHI
    • Bedrijfsprofiel
    • BUCHI Team
    • Nieuws
    • Evenementen
    • Büchi Visie
    • Wereldwijd
    • Vacatures

Your basket

Startpagina > Product overzicht > NIRSolutions > Products > NIRFlex N-500 > Polarization interferometer

NIRFlex N-500

 
  • Advantages
  • Good reasons
  • Polarization interferometer
  • Specifications

Polarization interferometer

Novel rugged crystal interferometer for superior performance

Polarization interferometer (click to enlarge)

The BUCHI polarization interferometer

BUCHI has adapted the successful quartz polarization interferometer by using crystals with a very high refractive index. This leads to optimum resolution and a compact design maintaining the advantage of insensitivity to mechanical disturbances.

The reason for the superior performance of this interferometer in rough environments is the difference of spatial movements and the optical path shifts for the two light beams in a birefringent crystal of variable thickness. Whereas in a Michelson type interferometer mechanical distortions directly affect the interference, such effects are reduced by a factor of 10 to 20 in a crystal interferometer.

Optimum resolution

Because NIR absorption bands are relatively broad in the case of liquids as well as for solid samples, resolutions higher than 8 cm-1 no longer improve the performance of NIR applications. On the contrary: Data collection with a higher resolution than the natural line width leads within a given measurement time to a poorer signal-to-noise ratio.

Furthermore, the data sets become unnecessarily large. It is therefore possible to keep the design of a polarization interferometer for optimum resolution extremely compact without losing its intrinsic advantage of ruggedness.

Principle of the polarization interferometer

When light strikes an anisotropic crystal, it is split into two components. These are polarized perpendicularly to each other and traverse the crystal at different phase velocities. The heart of the interferometer is its two prisms, which together form a cuboid. As soon as the previously 45° polarized light enters the crystal, the two partial beams traverse at different velocities.

As a result, they undergo a phase shift relative to each other which is systematically varied by moving one prism relative to the other. This changes the polarization of the combined beam. Therefore, after the second polarizer, a sinusoidal variation of the radiation is observed for monochromatic light. Radiation of several frequencies results in a superposition of various sine waves: an interferogram.

Principle of the polarization iterferometer (click to enlarge)
  • Top of page
  • Privacy
  • Sitemap
  • Impressum
  • Terms
  • Partnernet
  • Print
  • © 2012 BÜCHI Labortechnik AG
BÜCHI Labortechnik AG Logo BÜCHI Labortechnik GmbH
xxxxxx
xxxx xxxx
xxxx


www.buechigmbh.de
deutschland@buchi.com
Freecall 0800 414 0 414
T +49 201 747 49 0
F +49 201 747 49 20

© 2006 BÜCHI Labortechnik GmbH    
last modified: March 10 2011
  • Nederland
  • Wereldwijd

Contact Buchi

Wilt u:

  • Verzoek om een prijsopgave
  • Verzoek om meer informatie
  • A.u.b. contact met een specialist
  • A.u.b. contact met een verkoper
  • Waar te koop
  • Bestel een brochure
Configure your product

Product informatie

  • Brochures NIRFlex N-500 (pdf, 2.32Mb)
  • Products & Solutions EN (pdf, 1.33Mb)
  • NIRSolutions (pdf, 1.01Mb)
  • Alle downloads

Blijf op de hoogte

Ontvang onze nieuwsbrief 

Uw profiel

Log in


Uw wachtwoord vergeten?Nog niet geregistreerd? Doe dat hier.Waarom registeren?

Uw reactie

    Beoordeel deze pagina